Maintenance - Operations to be carried out after the first 60 hours of use.
- Check that all nuts and bolts are tight, particularly those retaining the crank case and
cylinder head. - Replace the lubricating oil.
Operations to be carried out daily
- Drain condensation by opening the valve located under the tank.
- Check the pump oil level.
- Check the engine oil level.
- Check all guards and covers are secure.
- Check for fuel and oil leaks.
- Check for air leaks
- Check for unusual noises or vibrations.
Operations to be carried out weekly (or more frequently in dusty environments)
- Remove the air filter element by undoing the screw and removing the filter cover
- Inspect the air filter and if worn or damaged, replace immediately.
Clean the air filter by blowing through from the inside to the outside with a low pressure
airline. - Reinstall the air filter, cover and screw.
- Check that the relief valve vents pump output and reduces engine speed when maximum pressure is reached.
- Check that the compressor restarts pressure build up automatically at 2 bar below the maximum pressure.
Operations to be carried out monthly
- Check belt tension.
- A weight of 3kg applied at the belt mid-point should give a deflection of approximately 10mm.
- If adjustment is required, maintain the alignment of the two pulleys.
Adjust by repositioning the engine using the screw adjuster.
Operations to be carried out every 100 hours
- Change the air filter element.
- Replace the pump lubricating oil with an oil suitable for temperatures ranging from -5°C to 45°C, viscosity Type 68 compressor oil.
- Drain the oil when it is warm, not hot, as this will allow the oil to drain more effectively.
- Place a suitable container under the drain plug and remove the drain plug.
- Once all the oil has drained, replace the drain plug and refill with new oil to the correct
level. - Replace the engine oil with semi-synthetic SAE 15W40 engine oil.
- Drain the oil when it is warn, not hot, as this allows the oil to drain more effectively.
- Place a suitable container under the drain plug and remove the drain plug.
- Once all the oil has drained, replace the drain plug and refill with new oil to the correct
level. - Check all tube fittings and electrical connections
- Inspect the pressure tank inside and out for damage or corrosion.