- Check power supply and power cord
- Ensure Red emergency Stop is not pressed in
- Water in air, check air dryer bypass valve is closed and ensure air dryer exit and entrance vales are open
- Auto Drain not working: check valve for damage and filter for blockage
For all other fault please refer to the Screw Compressor User Manual: Pages 63 onwards.